• 기술지원
산업용 밸브 | OEM 및 기술 지원
  • KOZO에 문의하기
KOZO Valve — Zhejiang Kozo Valve Co., 주식회사.
  • 집
  • 에 대한
  • 제품
    • 볼 밸브
      • 고정 볼 밸브
      • 편심 반구형 밸브
  • 산업용 밸브 기술 지원
    • 다운로드
    • 비디오
    • 산업용 밸브 공급 및 OEM 문의
  • 블로그
  • 연락하다
찾다
    한국어 한국어
    • English English
    • العربية العربية
    • 中文(简体) 中文(简体)
    • Nederlands Nederlands
    • Français Français
    • Deutsch Deutsch
    • Ελληνικά Ελληνικά
    • עברית עברית
    • Bahasa Indonesia Bahasa Indonesia
    • Italiano Italiano
    • 日本語 日本語
    • 한국어 한국어
    • پارسی پارسی
    • Português Português
    • Русский Русский
    • Español Español
    • Svenska Svenska
    • ภาษาไทย ภาษาไทย
    • Türkçe Türkçe
    • Tiếng Việt Tiếng Việt
메뉴
KOZO Valve — Zhejiang Kozo Valve Co., 주식회사.
찾다
집 볼 밸브 GU 스테인레스 스틸 수동 진공 볼 밸브
KOZO 고정형 볼 밸브
수동 고정 볼 밸브 Q47F-16C 플랜지, 주강
제품으로 돌아가기
공압 플랜지 볼 밸브
Q641F, Q641FH 공압 플랜지 볼 밸브
Vacuum ball valve
확대하려면 클릭하세요.

GU 스테인레스 스틸 수동 진공 볼 밸브

GU stainless steel manual vacuum ball valve Used to connect or disconnect the flow of media in vacuum (압력) 시스템 파이프라인. 응용 분야에는 진공이 포함됩니다., 낙농, 와인, 생명공학, 음식, 제약, 음료, 화장품, 및 화학 산업.

문의!
범주: 볼 밸브 태그: GU manual vacuum ball valve, 수동 진공 볼 밸브, 진공 볼 밸브
공유하다:
  • 설명
설명

GU 스테인레스 스틸 수동 진공 볼 밸브

GU stainless steel manual vacuum ball valve Used to connect or disconnect the flow of media in vacuum (압력) 시스템 파이프라인. 응용 분야에는 진공이 포함됩니다., 낙농, 와인, 생명공학, 음식, 제약, 음료, 화장품, 및 화학 산업.

제품명: 진공 볼 밸브

제품 모델: GU
공칭 직경: DN10~DN300
구조 유형: 구의

공칭 압력: 1.6Mpa~6.4Mpa
연결 방법: 플랜지, 스레드, 퀵 릴리스 플랜지, 노동 조합

적용온도: 180℃ 이하
작동 방식: 수동, 영적인, 전기 같은

밸브 본체 재질: 주강, 스테인레스 스틸
제조표준: GB (중국 국가 표준), 에서 (독일 표준), API (미국 표준), 안시 (미국 표준)

적용 가능한 미디어: 공기, 가스, 기름, 액체
제조업체:Zhejiang Kozo Valve Co., 주식회사.

GU stainless steel manual vacuum ball valve Main component materials:

밸브 본체, 밸브 커버, 밸브 스템: 스테인레스 스틸

물개: PTFE, 니트릴 고무, 불소고무, PPL.

Main Technical Specifications

Valve Leak Rate: ≤1.3×10⁻⁴ Pa·L/S

적용온도: -30~+150℃

-30~+150℃ (PPL Seal)

Applicable Range:

연결 유형: Loose Flange

Operating Pressure Range (Pa):

Loose Flange (GB6070, JB919): 0.6×10⁶~1.3×10⁻⁴

Welded Flange (GB6070, JB919): 1.6×10⁶~1.3×10⁻⁴

퀵 릴리스 플랜지 (GB4982): 0.1×10⁶~1.3×10⁻⁴

Threaded Connection: 1.6×10⁶~1.3×10⁻⁴

 

진공 볼 밸브: Principle and Applications

The vacuum ball valve is a type of vacuum valve developed in the 1990s. Its working principle is similar to that of a vacuum butterfly valve; the valve opens and closes by rotating a ball fixed on a rotating shaft by 90°. Vacuum ball valves open and close faster than vacuum butterfly valves, but are larger in size and have a higher leakage rate.

Because its valve body and stem are made of stainless steel, while the valve seat and packing are made of polytetrafluoroethylene (PTFE), it is suitable for media such as air, 물, 증기, acids, and alkalis. The medium temperature range is -25 to 120°C, and it is suitable for connecting or disconnecting the flow of acidic or alkaline gases and liquids in vacuum and pressure systems with working pressures of 1×10⁻³ to 1.6×10⁶ Pa.

Vacuum Ball Valve Types and Performance Parameters

Vacuum ball valves are available in three types: 수동, 전기 같은, and pneumatic.

a) Vacuum ball valves produced in my country include manual (GU type), 영적인 (GUQ type), 그리고 전기 (GUD type) models.

b) Vacuum pressure ball valves produced in my country include pneumatic (GQQ type) 그리고 전기 (GQD type) models. The technical performance parameters for these two types of vacuum pressure ball valves are: leakage rate less than or equal to 1.3 × 10⁻⁴ Pa·L/s; operating pressure range 10⁻⁴~1.6 MPa; operating temperature -30~150℃; valve body and ball material 316L; sealing material reinforced PTFE and fluororubber; using a 1/4 rotary pneumatic (or electric) 액추에이터, ensuring smooth operation; and providing electrical signal output for valve opening and closing.

 

GU Manual Vacuum Ball Valve Selection Analysis: Confirming Vacuum Requirements

Vacuum valves are generally classified into three categories based on their working pressure, i.e., vacuum level:

Low Vacuum Valve: Absolute pressure 101325~0.133 Pa

High Vacuum Valve: Absolute pressure 0.133~1.33 × 10⁻⁶ Pa

Ultra-High Vacuum Valve: Absolute pressure 1.33 × 10⁻⁶~1.33 × 10⁻¹⁰ Pa

The appropriate vacuum level of the vacuum ball valve must be selected based on the operating conditions.

GU Manual Vacuum Ball Valve Selection Analysis: Choosing the Connection Method

1. 플랜지 연결

This involves flanges at both ends of the valve body, corresponding to flanges on the pipeline, and the flanges are fixed in the pipeline with bolts. Flange connection is the most common connection type used in valves. Flanges include raised face (RF), flat face (FF), and raised face (MF), 등. This is the most commonly used connection type in vacuum valves.

2. Threaded Connection

Threaded connections are a simple connection method, commonly used for small valves. The valve body is machined according to various thread standards, with both internal and external threads available. These correspond to the threads on the pipe. This is a simple connection method commonly used for small valves. 예를 들어, some imported vacuum ball valves from VTON (USA) use threaded connections.

3. Compression Fitting Connection

The connection and sealing principle of a compression fitting connection is that when the nut is tightened, the compression fitting is subjected to pressure, causing its cutting edge to bite into the outer wall of the pipe. The outer conical surface of the compression fitting then seals tightly with the inner conical surface of the fitting body under pressure, thus reliably preventing leakage.

4. Clamp Connection

This is a quick connection method, requiring only two bolts, suitable for low-pressure valves that are frequently disassembled, such as sanitary valves.

This is a quick connection method, requiring only two bolts, suitable for low-pressure vacuum valves and sanitary valves that are frequently disassembled.

5. Welded Connection

The two ends of the valve body are machined into butt-welding bevels according to butt-welding requirements, corresponding to the welding bevels on the pipe, and fixed to the pipe by welding.

Choose the appropriate connection method required for the operating conditions.

 

GU Manual Vacuum Ball Valve Selection Analysis and Installation

1. Preparation

Before installation, confirm the absence of residual gas in the piping system. If present, clean it thoroughly. Prepare installation tools and accessories such as sealing rings.

2. Installation Location

The vacuum valve should be installed on a horizontal pipeline with a support to ensure stability. Avoid installing the valve in high-temperature or harsh environments.

3. Connecting the Pipeline

Connect the vacuum valve to the pipeline, paying attention to the installation direction and the correct use of the sealing ring. Tighten the bolts to the specified torque value.

4. Connecting Auxiliary Equipment

Connect auxiliary equipment as needed, such as vacuum gauges and vacuum pumps.

5. 점검

After installation, inspect the valve to confirm its smooth operation, proper sealing performance, and absence of leaks or other abnormalities.

 

GU Manual Vacuum Ball Valve Selection Analysis and Operation

1. Opening and Closing

The vacuum valve should be installed in the closed state. Before opening, ensure that all gas in the pipeline has been evacuated to avoid damage or impact on the valve from residual gas.

2. 점검

During daily use, the pipeline system should be inspected frequently, and any problems should be addressed promptly. 예를 들어, if the temperature or pressure in the pipeline system is found to be too high, the valve must be closed immediately to prevent damage.

3. Maintenance

Perform regular maintenance, such as cleaning and lubrication, to ensure the normal service life and performance of the vacuum valve.

Frequently Asked Questions:

Q: How do I determine if a vacuum valve is closed?

에이: This can be determined by observing the indicator on the vacuum valve, the inspection port, or whether there is gas flow in the connecting pipeline.

Q: What are the special installation locations for vacuum valves?

에이: Vacuum valves are generally not recommended for installation in locations with direct sunlight, high temperatures, or high humidity environments.

Q: Do the sealing rings of vacuum valves need to be replaced frequently?

에이: Sealing rings generally need to be replaced periodically to maintain their sealing performance.

In summary, proper selection, installation, and operation of vacuum valves can ensure the normal operation and efficiency improvement of piping systems.

관련상품

KOZO 고정형 볼 밸브
플랜지 연결부가 있는 흰색 기어 작동식 볼 밸브

산업용 A105N 유압 작동식 단조 강철 고정 볼 밸브

문의!
Q41F 미국 표준 볼 밸브

Q41F 미국 표준 볼 밸브

문의!
Q41H 하드 씰 볼 밸브, WCB 밸브 본체, PN16 플랜지 연결.

Q41H 하드 씰 볼 밸브, WCB 밸브 본체, PN16 플랜지 연결.

문의!
PBQ340H 수동 측면 장착형 편심 볼 밸브

PBQ340H 수동 측면 장착형 편심 볼 밸브

문의!
API607 측면 장착형 편심 볼 밸브 PBQ940H-10C

PQ940/PQ947 API 598,API6D 대구경 전기 편심 볼 밸브

문의!
Q41PPL 고온 볼 밸브

American Standard Q41F 수동 플랜지형 볼 밸브, 스테인레스 스틸과 탄소강으로 만들어진.

문의!
Q941F 전기 볼 밸브

Q941F 및 Q941Y 유형 PN16~PN63 전기 볼 밸브

문의!
전기 볼 밸브

Q941F-16P US API 스테인레스 스틸 전기 볼 밸브

문의!
KOZO Valve — Zhejiang Kozo Valve Co., Ltd.

Zhejiang Kozo Valve Co., 주식회사. 산업용 밸브를 제조하고 제품 개발을 제공하고 있습니다., 가공, 집회, 검사 및 고객 지원. 제품사양 및 OEM문의는 KOZO에 문의하세요..

소개하다

  • 에 대한
  • 산업용 밸브 공급 및 OEM 문의
  • 제품
  • 블로그
  • 다운로드
  • 연락하다

제품 카테고리

  • 볼 밸브
  • 편심 반구형 밸브
  • 고정 볼 밸브

문의하기

핸드폰: +86 13968878839

우편: jone@kozovalve.com

주소: 케중 산업단지, 차오시아 타운, 융자현, 저장성

저작권 © 2025 Zhejiang Kozo Valve Co., 주식회사. 모든 권리 보유.
  • 집
  • 에 대한
  • 제품
    • 볼 밸브
      • 고정 볼 밸브
      • 편심 반구형 밸브
  • 산업용 밸브 기술 지원
    • 다운로드
    • 비디오
    • 산업용 밸브 공급 및 OEM 문의
  • 블로그
  • 연락하다
찾고 있는 제품을 보려면 입력을 시작하세요..

제품문의