Ηλεκτρική κρυογονική σφαιρική βαλβίδα τριών κατευθύνσεων US API
The Q944F/Q945F electric cryogenic three-way ball valve consists of an angular stroke series intelligent actuator and a three-way ball valve. It is a rotary flow-switching valve with advantages such as tight closure, συμπαγής δομή, μικρό βάρος, and convenient maintenance.
Electric cryogenic three-way ball valve US API Product Name: Electric Cryogenic Three-Way Ball Valve
Μοντέλο προϊόντος: L-type Q944F/T-type Q945F
Ονομαστική Διάμετρος: DN15-DN300
Structure: Σφαιρικός
Ονομαστική πίεση: 1.6Mpa~6,4Mpa
Μέθοδος Σύνδεσης: Flange Applicable
Temperature: -40ºC~+180ºC
Drive Method: Electric Valve
Body Material: Ατσαλοσίδερο, Stainless Steel Manufacturing
Standard: γιγαμπάιτ (Κινεζικό Εθνικό Πρότυπο), ΑΠΟ (Γερμανικό Πρότυπο), API (American Standard), ANSI (American Standard) Εφαρμοσμένα μέσα: Νερό, Ελαιο, Αέριο,
Liquid Manufacturer: Zhejiang Kozo Valve Co., Ε.Π.Ε
The Q944F/Q945F electric cryogenic three-way ball valve consists of an angular stroke series intelligent actuator and a three-way ball valve. It is a rotary flow-switching valve with advantages such as tight closure, συμπαγής δομή, μικρό βάρος, and easy maintenance. Electric cryogenic three-way ball valves are widely used in the automated control of pipelines carrying corrosive media such as gases, liquids, ατμός, and oils. The electric three-way ball valve can switch the flow direction of the medium in the pipeline. It can also connect or close two mutually perpendicular channels. The four-seat sealed three-way ball valve has an aesthetically pleasing and compact structure. The electric cryogenic three-way ball valve can not only switch the flow direction of the medium but also connect the three channels. It can also close any channel while connecting the other two, flexibly controlling the merging or splitting of the medium in the pipeline. Επομένως, it is called an electric three-way directional ball valve.
Electric cryogenic three-way ball valve US API Main Technical Parameters and Performance
Ονομαστική διάμετρος DN (mm) 15 20 25 32 40 50 65 80 100 125 150 200
Allowable Differential Pressure (MPa) ≤Nominal Pressure
Operating Range 0~90°
Valve Body Type Two-stage split cast valve body
Valve Cover Type Integral type
Gland Type Bolted type
Sealing Packing V-type PTFE packing, PTFE-impregnated asbestos packing, υφασμάτινη συσκευασία αμιάντου, συσκευασία γραφίτη
Connection Method Flanged, Με σπείρωμα (suitable for 1/2″~2″)
Valve Core Type Three-way ball valve core
Flow Characteristics Approximately quick-opening characteristic
Διαρροή Q Μαλακό σφράγισμα: μηδενική διαρροή; Μεταλλική τσιμούχα: σύμφωνα με το GB/T4213-92, less than rated KV 0.01%
Basic Error ±1% Hysteresis ±1% Dead Zone ≤1%
Actuator Configuration JOX, 3810R, DZW, JHQ, PSQ electric actuators. Control methods: switch position indicator (έλεγχος διακόπτη δύο θέσεων), παθητικό σήμα επαφής, 1/5Κ ποτενσιόμετρο, έξυπνη προσαρμογή (4-20mA analog signal control).
Actuator Technical Parameters
Actuator Category: Imported JO Series Actuator Parameters; Imported 3610R Series Actuator Parameters; Imported JHQ Series Actuator Parameters
Power Supply Voltage: Standard: 220V AC Single Phase; Optional: 110V AC Single Phase, 380/440V AC Three Phase, 24V/110V/220V AC
Output Torque: 50N·M~2000N·M; 50N·M~1500N·M; 50N·M~3000N·M
Operating Range: 0~90°; 0~360°; 0~90°; 0~90°, 0°~270° προαιρετικά
Input Signal: Digital signal, 4~20mA analog signal; 4~20mA analog signal; Digital signal, 4~20mA analog signal
Feedback Signal: Digital signal, 4~20mA analog signal; 4~20mA analog signal Switching signals, 4-20mA analog signals
Χρόνος δράσης: 15s/30s/60s, 10s/15s/30s, 18s-112s
Protection devices: Overheat protection, Overload protection (built-in overheat and overload protection)
Ambient temperature: -30°C to 60°C, -20°C to +70°C
Manual operation: Same as the included handle, Mechanical clutch mechanism with handwheel operation
Mechanical limit switches: Electrical and mechanical dual limit switches, 2 external adjusting bolts
Protection rating: IP65, IP55, IP65, IP67, IP68 (customizable)
Explosion-proof rating: No explosion-proof, ExdⅡ, BT4, ExdⅡ, BT4, ExdⅡ, CT6
Position measurement: Optional switch or potentiometer, Proportional control unit, Potentiometer, μονάδα αναλογικού ελέγχου
Drive motor: 8W/E AC reversible motor, Squirrel-cage asynchronous motor
Inlet interface: PE1/2″ inlet wire lock 2-PF 1/2″ Inlet Line Lock (2 x PF 3/4″)
Housing Material: Aluminum Alloy, Steel, Aluminum Alloy, Steel, Aluminum Alloy, Aluminum Bronze, Polycarbonate
Outer Coating: Dry Powder, Epoxy Polyester, with superior corrosion resistance
Utilizing a unique electric braking circuit, resulting in high positioning accuracy, ευαίσθητος ενεργοποιητής, rapid start/stop, και ομαλή λειτουργία. It also features strong anti-interference, surge voltage resistance, and breakdown protection.
Suitable for frequently operating regulating circuits; with a duty cycle of 25%, it can operate 630-1200 times per hour.
Υλικά Κύριων Συστατικών
Component Name Material Name
Valve Body WCB 304(CF8) 316(CF8M) 316μεγάλο(CF3M)
Spherical Ball 2Cr13 + Νιτριδωμένο 304 316 316μεγάλο
Στέλεχος βαλβίδας 2Cr13 304 316 316μεγάλο
Sealing Ring PTFE, Reinforced PTFE (PPL), Παρα-Πολυστυρένιο, Εύκαμπτος Γραφίτης
Applicable Media Water, Αέριο, Steam, Ελαιο, και τα λοιπά. Corrosive Media such as Nitric Acid Acetic Acid Urea, και τα λοιπά.
Control Method: Electric cryogenic three-way ball valves are available in L-type and T-type, with the media flow direction shown in the diagram below. The L-type electric three-way ball valve is suitable for switching media flow direction, allowing two perpendicular channels to be connected. The T-type electric three-way ball valve is suitable for media diversion, συγχώνευση, or flow direction switching. The T-type orifice allows three channels to be interconnected or two channels to be connected. Electric three-way ball valves generally use a three-seat structure, but a four-seat structure can also be used according to user requirements.